Because the large volume of galvanized wire alloy elements in iron ore, can make the copper through the material thickening degree of strengthening, hardness, impact force, strength resistance, closing rate, elongation, so alloy iron in the exercise of good iron, is an important supplementary element. The difference between galvanized wire and general iron wire is very big, general iron wire is cheap, and because iron is not very stable, easy to rust in wet places, so the stability is not very good, life is not very long.
The barbed rope is twined and braided to save transportation space. It is usually wound into bundles.
- Determine the size of the dog cage based on the dog’s actual adult size. In general, the cage should be three times the size of the dog’s body and give him enough room to turn around and so on.
- One is to do a good job of galvanized wire packaging, avoid bumping, to ensure the integrity of the zinc layer;
In order to pack and bundle galvanized wire on the surface of the deposit layer to remove the surface film, surface inclusion and other defects can be found and treated by conventional technology; Excess foam is caused by soaps and saponable fatty surfactants being brought into the tank. Moderate foam formation rates may be harmless. Small homogeneous particles of large denier present in the tank can stabilize the foam layer. To remove surface active substances by matting with activated carbon. Or filtration to make the foam less stable, which are effective measures; Other measures should also be taken to reduce the intake of surfactant. The electroplating speed can be significantly reduced by the introduction of organic matter. Although the chemical formula is conducive to a high deposition rate, the coating thickness cannot meet the requirements after the organic matter is loaded, so activated carbon can be used to treat the tank.
Post time: 09-06-22Poor pretreatment before plating; Bath temperature is too low; Poor quality of additives or too many additives and organic impurities will cause poor bonding. The quality of additives also has an effect on coating foaming. Some additives react incompletely during synthesis and continue to polymerize during long-term storage or use. The additive tends to distort the crystal lattice and cause stress, causing the coating to bubble.
The hook mesh is a good material for flood control and flooding. Can also be used for arts and crafts manufacturing, mechanical equipment transport network mountain beautification network – high strength steel wire grid (hook mesh, diamond mesh) hook mesh mountain protection application principle, hook mesh interests, mesh uniform, flat, woven concise, hook woven, beautiful and generous, net, net width, wire diameter is thicker, not easy to corrosion, long life, strong usefulness.
- Alias: gabion mesh, heavy hexagonal mesh, ecological mesh, wire mesh, etc.
Post time: 28-06-22
Post time: 26-12-22- Aliases: Gabion mesh, heavy hexagonal mesh, ecological mesh, wire mesh, etc.
- 1. Choose according to the size of your dog
Removal of surface-active substances by activated carbon matting. Or make the bubble unstable according to overworry, these are all reasonable countermeasures; Other strategies should also be used to minimize the amount of surfactant taken in. The introduction of organic matter can make the electroplating process speed drop sharply. Galvanized iron wire blackening can be effectively prevented, such as: the work site to keep dry, reduce and do not use chemicals, operators with clean gloves and so on. In addition, hot dipping zinc factory can be required, after dipping zinc must be passivation treatment, passivation treatment of zinc has a better anti-discoloration effect, can effectively prolong the discoloration time, the combination of the two, discoloration should be able to solve. Galvanized iron wire has good toughness and elasticity, the amount of zinc can reach 300 g/square meter. It has the characteristics of thick galvanized layer and strong corrosion resistance.
- The mixture of rare earth and aluminum enhances the fluidity of zinc liquid, makes the coating more uniform, and also reduces the zinc consumption. Hot dip galvanized wire has better protection performance than cold galvanized wire, which makes it good application in chemical experimental equipment. Hot dip wire coating thicker, so that it has good corrosion resistance, can be in the outdoor sun and rain and other harsh environment can be maintained for decades, so hot dip galvanized wire is widely used in construction, traffic guardrail and other outdoor facilities.
The service life of the original galvanized iron welding mesh is very limited. Generally, good iron railings can only be used for about 2 years, and then renovated until the service life, which is not only time-consuming but also has safety risks. After the appearance of zinc-steel railings, the service life has been increased to a great extent in the post-processing. Generally, it can be used for at least 20 years. To improve the service life of zinc steel railings, we first have a brief understanding of the product characteristics of railings. Then from the maintenance aspect, it is necessary to maintain. Maintenance method of electric welding mesh:
Post time: 18-10-22For the specification of galvanized wire, the galvanized wire produced by our factory can range from No.8 to No.22, which refers to the BWG standard, that is, from about 4mm to 0.7mm, which can basically cover the type required by customers. As for the raw material of galvanized wire, normally, we use Q195 mild steel, and some factories will also use SAE1006 or SAE1008. The following is the zinc coating, for galvanized wire, this thing is more important, the general zinc coating is about 50g/m2 to 80g/m2, some customers need high zinc galvanized wire, zinc coating can reach 200g/m2 to 360g/m2. The tensile strength of galvanized wire is usually 350n/m2 to 800n/m2. Then there is the packaging specification of galvanized wire. The specifications of small rolls of galvanized wire are 50kg/ roll, 100kg/ roll and 200kg/ roll. Of course, there are large rolls of galvanized silk, the weight can reach 300kg/ roll or 800kg/ roll.
- In the production of its own, to avoid injury, wearing the corresponding work clothes is very necessary, so that not only can avoid the occurrence of accidents, but also can better realize the production and processing of products. The application of black iron wire in the process is mainly through the hot metal billet rolled into a six-and-a-half-millimeter wire, and then put it into the drawing device to draw into different diameter of the wire, gradually reduce the aperture of the drawing disk, cooling and annealing, coating and other processes to make a variety of different specifications of the wire.
The temperature of large roll galvanized wire should be controlled at 30 to 50℃ during electroplating. Because the chloride ions in the bath are very corrosive, quartz glass heaters are generally used. Continuous production does not need heating, but needs cooling. Cooling can be in the groove side row thin wall plastic pipe, through the flow of tap water cooling, can also be used as a titanium pipe temperature control device.
- In fact, although galvanized hook net is a useful material for iron products, but fundamentally speaking, modern hook net through continuous transformation and improvement, even if it seems to be not useful products, also have a role in its use, here we can turn our attention to people abandoned galvanized hook net.
- Professional materials in use can meet the needs of most consumers for materials, and the quality of these products is certainly to withstand the test, so if you really can not make up your mind, choose what kind of barbed rope, it is recommended to choose the best blade barbed rope.
The hot dip galvanized hexagonal net is made of low carbon steel wire by mechanized braided welding and then by hot dip zinc treatment. Net color bright white, thick zinc layer, uniform mesh, mesh surface smooth, solder joint tensile resistance, high corrosion resistance.
- Plastic spraying is often referred to as electrostatic powder spraying. It is the use of electrostatic emitter to make plastic powder charged, adsorbed on the surface of the iron plate, and then baked at 180~220℃ to melt the powder and adhere to the metal surface. Plastic spraying products are mostly used in indoor boxes, and the paint film appears flat or matte. Spray powder mainly acrylic powder, polyester powder and so on.
- Material: low carbon steel wire, stainless steel wire, PVC wire, copper wire
There is no adhesion test of powder spraying or fluorocarbon spraying on packaged galvanized wire, but there are two points for reference: first, in sealed or air-free environment, non-metallic volatiles can corrode zinc coating; Second, zinc at higher than 230 degrees (c) will cause the matrix metal brittle. And powder spraying and fluorocarbon spraying are to be baked at a higher temperature and in a sealed environment, causing rapid corrosion of zinc, resulting in loose corrosion film resulting in coating adhesion decline, and even lead to (matrix) steel wire brittle situation may exist.
Maintenance is indispensable in the use of galvanized wire. Large coils of galvanized silk should be coated with oil, fiber core immersion oil, oil is required to protect the fiber core is not rotten, not rust, wire moisture fiber, and from the internal lubrication wire rope. Surface coating so that all wire rope strands in the surface, are evenly coated with a layer of rust-proof lubrication grease, which for friction lifting and mineral water large mine rope, to be coated with grinding and water-resistant black oil grease. Coated with red oil with strong film and good rust resistance, it is required to have a thin oil layer, which is easy to keep clean during operation.
- Galvanizing can be done by zincate galvanizing or chloride galvanizing. Appropriate additives should be used to obtain a coating that meets the requirements of this standard. Light treatment should be carried out after light plating. The parts that need to be dehydrogenated for passivation should be passivated after dehydrogenation. Before passivation, 1%H2SO4 or 1% hydrochloric acid should be applied for activation for 5~15s. Passivation shall be treated with colored chromate unless otherwise specified in the design drawings.